LC-W Channel Lintel portfolio
Application and advantages
- For walls constructed from: AAC block, Ceramic brick, Silicate brick, Gypsum block, Concrete block and others
- For internal walls with thikness from 100 mm to 200 mm
- Applications in wall with fire rating up to 60 and 120 min (Integrity & Insulation) in accordance to the required plaster thickness
- For walls with higher requirments to firerating, thermal conductivity and sound insulation
Product Name | Product code | Width, W (mm) | Height, H (mm) | Thikness, t (mm) | Overall Dimensions | Price |
---|---|---|---|---|---|---|
StiFlex Channel Lintel with stone wool infill | LC070706-W | 70 | 70 | 0.6 | 70mm x 70mm x 0.6mm | by request |
StiFlex Channel Lintel with stone wool infill | LC070908-W | 70 | 90 | 0.8 | 70mm x 90mm x 0.8mm | by request |
StiFlex Channel Lintel with stone wool infill | LC090908-W | 90 | 90 | 0.8 | 90mm x 90mm x 0.8mm | by request |
StiFlex Channel Lintel with stone wool infill | LC120908-W | 120 | 90 | 0.8 | 120mm x 90mm x 0.8mm | by request |
StiFlex Channel Lintel with stone wool infill | LC121408-W | 120 | 140 | 0.8 | 120mm x 140mm x 0.8mm | by request |
Technical information: | |
---|---|
Design meets with specifications of: |
• BS 5977-1 Method for assessment of load • BS EN 845-2 Specifications of ancillary components for masonry • BS 5950-5 Structural use of steelwork in building - Code of practice for design of cold formed sections |
Manufacture complies with requirements of: |
• EN 10162 Cold rolled steel section - Technical delivery conditions - Dimensions and cross-sectional tolerances |
Material conforms to specifications of: |
• JIS G 3302 SGC340 for galvanized steel with both satisfying non-alloy Zn 275 requirements of min. triple spot average zinc coating mass of 275g/m² • Stone wool insulation 120 kg/m³ |
Fire Insulation tested in accordance with: |
• EN 1365-1 Fire resistance tests for loadbearing elements for walls, achieved up to 2-hour rating for loadbearing capacity, integrity and insulation performance Note: Fore fireinsulation requirement exceeding 2-hour complying to EN 1365-1, alternative StiFlex lintel can be provided |