LC-W Channel Lintel portfolio

Application and advantages

  • For walls constructed from: AAC block, Ceramic brick, Silicate brick, Gypsum block, Concrete block and others
  • For internal walls with thikness from 100 mm to 200 mm
  • Applications in wall with fire rating up to 60 and 120 min (Integrity & Insulation) in accordance to the required plaster thickness
  • For walls with higher requirments to firerating, thermal conductivity and sound insulation
Product Name Product code Width, W (mm) Height, H (mm) Thikness, t (mm) Overall Dimensions Price
StiFlex Channel Lintel with stone wool infill LC070706-W 70 70 0.6 70mm x 70mm x 0.6mm by request
StiFlex Channel Lintel with stone wool infill LC070908-W 70 90 0.8 70mm x 90mm x 0.8mm by request
StiFlex Channel Lintel with stone wool infill LC090908-W 90 90 0.8 90mm x 90mm x 0.8mm by request
StiFlex Channel Lintel with stone wool infill LC120908-W 120 90 0.8 120mm x 90mm x 0.8mm by request
StiFlex Channel Lintel with stone wool infill LC121408-W 120 140 0.8 120mm x 140mm x 0.8mm by request
Technical information:  
Design
meets with specifications of:
• BS 5977-1 Method for assessment of load
• BS EN 845-2 Specifications of ancillary components for masonry
• BS 5950-5 Structural use of steelwork in building - Code of practice for design of cold formed sections
Manufacture
complies with requirements of:
• EN 10162 Cold rolled steel section - Technical delivery conditions - Dimensions and cross-sectional tolerances
Material
conforms to specifications of:
• JIS G 3302 SGC340 for galvanized steel with both satisfying non-alloy Zn 275 requirements of min. triple spot average zinc coating mass of 275g/m²
• Stone wool insulation 120 kg/m³
Fire Insulation
tested in accordance with:
• EN 1365-1 Fire resistance tests for loadbearing elements for walls, achieved up to 2-hour rating for loadbearing capacity, integrity and insulation performance
Note: Fore fireinsulation requirement exceeding 2-hour complying to EN 1365-1, alternative StiFlex lintel can be provided